Product Details
Place of Origin: Beijing
Brand Name: GOMECY
Certification: CE, ISO
Model Number: GMS A69
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: Aluminum box
Delivery Time: 5-7 days
Payment Terms: T/T, Western Union
Supply Ability: 500 pcs per month
Product Name: |
Focused Shockwave Therapy |
Technology: |
Electromagnetic ESWT Machine |
Function 1: |
Physiotherapy Equipment |
Function 2: |
Deep Tissue Pain Relief |
Function 3: |
Shockwave Therapy For Veterinary |
Model: |
A69 |
Display: |
15.6-inch Touch Screen |
Power Supply: |
AC 110V–220V ±10% |
Rated Power: |
≤500VA |
Safety Class: |
Class I |
Operation Mode: |
Plug-in |
Applicator Heads: |
5 Interchangeable Silicone Heads |
Penetration Depth: |
4~66mm |
Treatment Time: |
~10 Minutes Per Session |
Pulse Frequency: |
1~15Hz |
Strength Grade: |
1~20Level |
Water Tank: |
3 L |
Product Name: |
Focused Shockwave Therapy |
Technology: |
Electromagnetic ESWT Machine |
Function 1: |
Physiotherapy Equipment |
Function 2: |
Deep Tissue Pain Relief |
Function 3: |
Shockwave Therapy For Veterinary |
Model: |
A69 |
Display: |
15.6-inch Touch Screen |
Power Supply: |
AC 110V–220V ±10% |
Rated Power: |
≤500VA |
Safety Class: |
Class I |
Operation Mode: |
Plug-in |
Applicator Heads: |
5 Interchangeable Silicone Heads |
Penetration Depth: |
4~66mm |
Treatment Time: |
~10 Minutes Per Session |
Pulse Frequency: |
1~15Hz |
Strength Grade: |
1~20Level |
Water Tank: |
3 L |
Shockwave Therapy Machine Providing Effective Support in Sports Recovery and Musculoskeletal Physical Therapy Programs
The GOMECY A69 is an electromagnetic focused shockwave system designed for professional rehabilitation and physical therapy. It converts electrical energy into mechanical pulses and uses a focusing structure to deliver acoustic energy toward a selected treatment depth.
With an intuitive 15.6-inch touchscreen, adjustable operating frequency and energy settings, and interchangeable silicone depth pads, the A69 gives trained operators flexibility when setting up sessions for different body areas and tissue depths. Its compact integrated design and water-cooling circuit support routine use in professional facilities.
![]()
Main Uses
1) Electromagnetic energy conversion: An internal electromagnetic generator creates a pulsed magnetic field that drives a diaphragm to vibrate, converting electrical energy into mechanical energy.
2) Focused energy delivery: A specially designed focusing structure concentrates the generated acoustic pulses toward a selected focal region. Interchangeable silicone pads are used to select the corresponding depth range.
3) Tissue stimulation: Focused acoustic pulses deliver mechanical stimulation to the selected area. The operator adjusts frequency and energy according to the treatment plan, the area being addressed, and the individual’s response.
The system is non-invasive in operation and does not require an incision. Coupling medium should be applied as directed in the operating instructions to support effective energy transmission.
![]()
Application Settings
| Parameter | Specification |
| Product name | Electromagnetic Focused Shockwave System |
| Model | A69 |
| Technology | Electromagnetic focused shockwave |
| Operating frequency | 1–15 Hz |
| Energy / strength setting | Level 1–20 |
| Power | 10–500 W |
| Rated power in user manual | 300 W |
| Display | 15.6-inch touchscreen |
| Focusing / penetration depth | Seller-provided overall range: 4–66 mm |
| Treatment handle | 1 pc |
| Silicone depth pads | 5 pcs |
| Water tank / water circuit | 3 L |
| Power supply | AC 110–220 V ±10% |
| Product dimensions | 59 × 65 × 45 cm |
| Total weight | 25.5 kg |
| Pad | Depth range |
| No. 1 | 35–75 mm |
| No. 2 | 25–60 mm |
| No. 3 | 15–45 mm |
| No. 4 | 5–30 mm |
| No. 5 | 5–20 mm |
Q1. What technology does the A69 use?
It uses an electromagnetic generator to create mechanical pulses, which are then focused toward a selected depth.
Q2. How many silicone pads are included?
The stated configuration includes five interchangeable silicone depth pads.
Q3. What depth ranges are available?
The manual lists five pad ranges: 35–75 mm, 25–60 mm, 15–45 mm, 5–30 mm, and 5–20 mm.
Q4. Can frequency and energy be adjusted?
Yes. The manual describes an operating frequency of 1–15 Hz and adjustable energy levels.
Q5. Is the system easy to operate?
The A69 features a 15.6-inch touchscreen and a handpiece with pause and frequency adjustment buttons. Operators should complete appropriate training before use.
Q6. Which areas can be selected on the interface?
The manual shows options including the shoulder, elbow, wrist, hip, knee, hamstring, Achilles tendon, ankle/foot, waist/back, and neck/shoulder areas.
Q7. Does the device require water before operation?
Yes. The users to fill the unit and handpiece with the required water and check for air before operation.
Q8. How often should the water be changed?
Changing the water approximately every 15 days during frequent use. Always follow the current manual and the manufacturer's maintenance guidance.
Q9. Who should operate the A69?
Only trained and appropriately qualified professionals should operate the system.
Q10. Can it be used for every customer or every body area?
No. Suitability depends on individual assessment, the treatment area, contraindications.