Product Details

Place of Origin: Beijing

Brand Name: GOMECY

Certification: CE, ISO

Model Number: GMS PrismaLift Q4

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Aluminum box

Delivery Time: 5-7 days

Payment Terms: T/T, Western Union

Supply Ability: 500 pcs per month

Get Best Price
Highlight:

Endolift Laser Machine 12.1 Inch Interface

,

Endolift Laser Machine Multiple Language Options

,

Endolift Laser Machine for Surgical Professionals

Product Name:
Internal Fiber Lifting Machine
Technology:
Subdermal Fat Melting Laser
Function:
Vascular Spider Vein Removal
Laser Wavelengths:
1210nm+980nm+1470nm+635nm
Max Output Power:
5W+20W+3W+200mW
Fiber Transmission:
SMA905 Standard / Biquartz Optical Fiber
Operating Interface:
12.1-inch HD Color Touch Screen
Pulse Duration:
15ms - 60ms (Adjustable)
Pulse Frequency:
1Hz - 9Hz (Variable Speed)
Cooling System:
Air+Tec+Liquid Cooling
Aiming Beam:
650nm Red Diode Laser (Adjustable Intensity)
Net Weight:
25KG (Portable High-Power Design)
Voltage Supply:
AC 100V-240V / 50-60Hz
Operation Modes:
Continuous Wave (CW) / Single Pulse / Repeat Pulse
Product Name:
Internal Fiber Lifting Machine
Technology:
Subdermal Fat Melting Laser
Function:
Vascular Spider Vein Removal
Laser Wavelengths:
1210nm+980nm+1470nm+635nm
Max Output Power:
5W+20W+3W+200mW
Fiber Transmission:
SMA905 Standard / Biquartz Optical Fiber
Operating Interface:
12.1-inch HD Color Touch Screen
Pulse Duration:
15ms - 60ms (Adjustable)
Pulse Frequency:
1Hz - 9Hz (Variable Speed)
Cooling System:
Air+Tec+Liquid Cooling
Aiming Beam:
650nm Red Diode Laser (Adjustable Intensity)
Net Weight:
25KG (Portable High-Power Design)
Voltage Supply:
AC 100V-240V / 50-60Hz
Operation Modes:
Continuous Wave (CW) / Single Pulse / Repeat Pulse
Endolift Laser Machine Providing 12.1 Inch Operation Interface and Multiple Language Options for Surgical Professionals

Endolift Laser Machine Providing 12.1 Inch Operation Interface and Multiple Language Options for Surgical Professionals

Product Description

GOMECY PrismaLift Q4 brings three near-infrared wavelengths and one visible red wavelength into a single professional platform. The specified wavelength outputs are 1210 nm at 5 W, 980 nm at 20 W, 1470 nm at 3 W and 635 nm at 200 mW. These wavelengths provide different optical interaction characteristics for application-specific workflows.

Fiber-optic coupling delivers laser energy through compatible accessories. Continuous and pulse modes allow trained operators to work within the validated settings for the intended procedure. The 12.1-inch interface provides a central operating display, while air, thermoelectric and liquid cooling support equipment thermal management.

1.png

 

Key features

• Four specified wavelengths in one platform: 1210 nm, 980 nm, 1470 nm and 635 nm.

• Fiber-coupled output with a specified 3 m fiber length.

• 12.1-inch operation interface with English or OEM language options.

• Continuous and pulse output modes; specified pulse width of 15–60 ms and repetition rate of 1–9 Hz.

• Air, TEC and liquid cooling for equipment heat management.

 

Applications and Working Principles

Main uses

Professional surgical workflows: fiber-delivered energy for soft-tissue photothermal work, including cutting and coagulation only where these uses are covered by the device instructions and applicable authorization.

Human physiotherapy workflows: surface-directed light delivery using the appropriate treatment accessory and a validated protocol. The 635 nm red-light channel provides a visible wavelength relevant to superficial photobiomodulation applications.

How the wavelengths work

980 nm: near-infrared energy interacts with water and blood-related absorbers in tissue. At suitable energy levels, absorption produces heat. The effect depends on output, delivery geometry, exposure duration and tissue characteristics.

1470 nm: near-infrared energy is strongly absorbed by water. This supports localized energy deposition in water-containing tissue. The wavelength alone does not establish a particular contouring result or collagen response.

1210 nm: this near-infrared wavelength lies near a spectral region associated with water and lipid absorption. It provides an additional tissue-interaction option, but should not be described as exclusively or automatically targeting fat.

635 nm: visible red light is relevant to photobiomodulation at appropriate irradiance and exposure. Output power alone does not establish dose, effective depth or a clinical outcome. A suitable surface accessory and validated protocol are necessary.

2.png

Application settings

Professional surgical facilities and aesthetic clinical environments may evaluate the platform for authorized fiber-based procedures. Human physiotherapy and rehabilitation facilities may evaluate compatible surface-light applications within their permitted scope of practice. Distributors and OEM buyers can specify the wavelength configuration, fiber options and interface language for their project.

Technical Specifications

Item Specification
Brand and model GOMECY PrismaLift Q4
Laser type and output Diode laser; fiber-optic coupling
Wavelengths 1210 nm + 980 nm + 1470 nm + 635 nm
Specified output by wavelength 1210 nm: 5 W
980 nm: 20 W
1470 nm: 3 W
635 nm: 200 mW
Power supply AC 100–240 V
Rated frequency 50/60 Hz
Operation interface 12.1 inches
Interface language English or OEM
Output modes Pulse mode and continuous mode
Pulse width 15–60 ms
Pulse repetition rate 1–9 Hz
Specified fiber length 3 m
Fiber core options 400 μm standard; 200 μm upgrade option
Cooling system Air + TEC + liquid cooling
Aiming beam 650 nm
Delivery fiber package 2 × 600 μm blue direct fibers; or
1 × 400 μm fiber + 1 × 600 μm fiber
Handpiece set One laser-assisted contouring handpiece set with 5 needles
Additional treatment accessory One gray tip specified for the 635 nm channel

2.png

 

Advantages:

 

  • Four-Wavelength Technology: Integrates 1210nm, 980nm, 1470nm, and 635nm wavelengths for versatile applications.

  • Four-Channel Output: Supports independent channel output or simultaneous output from all four channels.

  • Multifunctional Applications: Designed for various laser surgery and physiotherapy applications.

  • Versatile Treatment Options: Suitable for applications such as Endolift, EVLT, laser lipolysis, and soft tissue procedures, subject to the applicable configuration.

  • 635nm Red Light Therapy: Provides a dedicated red-light channel for superficial photobiomodulation applications.

  • 12.1-Inch Touchscreen: Offers a large, intuitive interface for convenient operation.

  • Flexible Operating Modes: Supports both pulse mode and continuous mode.

  • Adjustable Treatment Settings: Pulse width of 15–60ms and frequency of 1–9Hz.

  • Dual Fiber Options: Supports a standard 400μm fiber core or an upgraded 200μm option, according to configuration.

  • Advanced Cooling System: Combines air, TEC, and liquid cooling technologies.

  • 3-Meter Fiber Length: Provides flexibility for positioning and operation.

  • OEM Customization: Supports English-language operation and OEM language options.

    3.png4.png

 

 

Accessory package:

  • 600 μm Blue Direct Fiber × 2 pcs
    Or: 400 μm Fiber × 1 pc + 600 μm Fiber × 1 pc

  • Laser-Assisted Contouring Handpiece Set × 1 set

  • Needles × 5 pcs

  • Gray Treatment Tip (635nm) × 1 pc

    5.png

FAQ

 

Q1: What wavelengths are included in this version?

This version specifies 1210 nm, 980 nm, 1470 nm and 635 nm.

Q2: What are the specified output powers?

The supplied values are 5 W at 1210 nm, 20 W at 980 nm, 3 W at 1470 nm and 200 mW at 635 nm. Supports independent channel output or simultaneous output from all four channels.

Q3: Can the platform be evaluated for both surgery and human physiotherapy?

Yes, these are the two stated application directions. Each proposed use still requires a compatible accessory, an applicable protocol and confirmation against the current device instructions and destination-market requirements.

Q4: Does the 1210 nm wavelength selectively remove fat?

Wavelength alone does not establish selective fat removal. Tissue interaction also depends on composition, energy delivery, fiber design and the complete validated procedure.

Q5: Is the 635 nm channel the same as the aiming beam?

No. The 635 nm output channel and a separate 650 nm aiming beam. 635 nm light facilitates lipid metabolism and provides anti-inflammatory, soothing effects; it enhances safety while maintaining fat-dissolving efficacy and shortening the recovery period. It can serve both as an indicator light and as a therapeutic light source.

Q6: Which fiber diameter is standard?

The Standard accessory package have 2 pcs 600 μm fibers, or one 400 μm and one 600 μm fiber. depend on your needs.

Q7: Are pulse and continuous modes available?

Both modes are specified. The pulse range is 15–60 ms at 1–9 Hz. Supported combinations and channel-specific settings should follow the current instructions.

Q8:Can the interface language be customized?

English or OEM language options are specified. Confirm the requested language and its availability before ordering.

 