Product Details
Place of Origin: Beijing
Brand Name: GOMECY
Certification: CE
Model Number: GMS 980+1470nm Diode laser 6+1 Panacea
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: Aluminum box
Delivery Time: 5-7 days
Payment Terms: T/T, Western Union
Supply Ability: 500 pcs per month
Product Name: |
Dual-Wavelength Laser |
Technology: |
Diode Laser Lipolysis |
Function 1: |
Body Contouring Device |
Function 2: |
Non-Surgical Fat Reduction |
Function 3: |
Laser-Assisted Liposuction |
Laser Type: |
Pulse, Cw, Single |
Wavelength: |
980nm + 1470nm |
Power: |
20W (980nm) + 3W (1470nm) Standard |
Pulse Width: |
15–100ms |
Frequency: |
1–20Hz |
Beam Transmission: |
Biquartz Optical Fiber |
Pilot Beam: |
Red Diode Laser 650nm, <5MW |
Screen: |
10.4 Inches |
Machine Size: |
36 × 37 × 24 Cm |
Power Input: |
AC 100–240V, 50/60Hz |
Product Name: |
Dual-Wavelength Laser |
Technology: |
Diode Laser Lipolysis |
Function 1: |
Body Contouring Device |
Function 2: |
Non-Surgical Fat Reduction |
Function 3: |
Laser-Assisted Liposuction |
Laser Type: |
Pulse, Cw, Single |
Wavelength: |
980nm + 1470nm |
Power: |
20W (980nm) + 3W (1470nm) Standard |
Pulse Width: |
15–100ms |
Frequency: |
1–20Hz |
Beam Transmission: |
Biquartz Optical Fiber |
Pilot Beam: |
Red Diode Laser 650nm, <5MW |
Screen: |
10.4 Inches |
Machine Size: |
36 × 37 × 24 Cm |
Power Input: |
AC 100–240V, 50/60Hz |
The GOMECY 1470nm and 980nm diode laser machine is a compact, fiber-coupled system for professional equipment procurement. It combines two wavelengths in one platform, with a combined output of up to 30W and a 10.4-inch touchscreen for parameter selection.
The system provides continuous-wave and pulsed operating modes. Interchangeable applicators and a separate cooling hammer support different equipment configurations.
![]()
The platform is designed to deliver laser energy through compatible optical fibers and applicators for professional aesthetic and skin-care workflows within its documented intended use.
· Professional aesthetic equipment workflows using compatible surface applicators.
· Localized optical energy delivery through a fiber-optic handpiece.
· Different applicator configurations for professional skin-care and nail-area workflows, where permitted by the applicable intended use.
· Separate local cooling through the supplied cooling hammer.
![]()
· Dual wavelengths: 1470nm and 980nm are delivered together, as described in the supplied manual.
· Combined output: adjustable output from 0.5W to 30W; 30W is the combined rating rather than 30W per wavelength.
· Touchscreen interface: a 10.4-inch display provides access to operating parameters.
· Two operating modes: continuous-wave and pulsed output support different equipment settings.
· Fiber-optic delivery: compatible fibers and interchangeable applicators provide configuration flexibility.
· Aiming beam: a 650nm visible aiming beam supports positioning.
· Separate cooling accessory: a cooling hammer is included in the manual's accessory list.
· Compact housing: the main unit measures 360 × 370 × 240mm, with a listed net weight of 5kg.
The system uses semiconductor laser sources to generate light at 1470nm and 980nm. Optical fibers carry the laser energy from the main unit to a compatible applicator.
The two wavelengths interact differently with absorbing components in tissue. In general, 1470nm has stronger water absorption than 980nm. Absorbed laser energy can be converted into heat; the resulting interaction depends on wavelength, delivered power, exposure time, applicator geometry and the properties of the exposed area.
Power, pulse settings and repetition frequency are selected through the touchscreen within the limits of the relevant program. These technical controls do not by themselves establish a clinical result. Operators must follow the model-specific instructions, training requirements and applicable laser protection procedures.
![]()
| Parameter | Specification |
| Brand | GOMECY |
| Product type | Dual wavelength diode laser system |
| Laser wavelengths | 1470nm + 980nm |
| Wavelength output | Simultaneous output, according to the supplied manual |
| Combined laser output | Up to 30W |
| Adjustable output range | 0.5–30W |
| Optical delivery | Fiber-optic coupling |
| Operating modes | Continuous wave / Pulse |
| Pulse width | 15–100ms in the general specification table; program dependent |
| Frequency | 1–20Hz in the general specification table; program dependent |
| Aiming beam | 650nm |
| Display | 10.4-inch touchscreen |
| Fiber length | 2m / 3m, as listed in the manual; confirm supplied configuration |
| Main-unit cooling | Air cooling |
| Cooling accessory | Separate cooling hammer |
| Power supply | AC 100–240V, 50/60Hz |
| Interface language | English; OEM language option subject to confirmation |
| Main-unit dimensions | 360 × 370 × 240mm |
| Listed net / gross weight | 5kg / 13kg |
| Flight case dimensions | 460 × 440 × 340mm |
![]()
Qualified professional aesthetic facilities: for equipment selection and operation within the model's documented intended use and local requirements.
Professional equipment distributors: for comparing wavelength specifications, electrical compatibility, accessory packages and documentation for a defined market.
Professional training and demonstration facilities: for supervised equipment familiarization, interface demonstrations and accessory identification by qualified personnel.
The device is not presented as a home-use product. Specialized procedures require the relevant professional qualifications, facility conditions and model-specific authorization.
![]()
Q1. Is the output 30W for each wavelength?
No. The manual lists 30W as the combined output of the 1470nm and 980nm wavelengths.
Q2. Can the wavelengths be selected independently?
The supplied manual describes simultaneous output without separate wavelength selection. Confirm the delivered model's interface before ordering.
Q3. Are all pulse and frequency settings available in every program?
No. The manual gives program-specific ranges. The general specification table should not be interpreted as the available range for every application.
Q4. Does the cooling hammer cool the main unit?
The main unit uses air cooling. The cooling hammer is a separate accessory with a different function.
Q5. Can the interface language be customized?
Yes it have OEM language options. Available languages, costs and lead time should be confirmed for the order.
Q6. What information should buyers review before purchase?
Confirm the exact model, accessory package, intended use, applicable documentation, operator requirements and destination-market acceptance. Warranty and service terms should be agreed in writing.