Product Details
Place of Origin: Beijing
Brand Name: GOMECY
Certification: CE
Model Number: GMS C6 Verticle
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: Aluminum box
Delivery Time: 5-7 days
Payment Terms: T/T, Western Union,
Supply Ability: 500 pcs per month
Product Name: |
Fractional CO2 Laser |
Technology: |
Medical CO2 Laser Machine |
Function: |
Dermatology CO2 Laser |
Working Mode: |
Single Pulse, Continuous Pulse, Repeated Pulse |
Laser Type: |
Metal Tube |
Laser Wavelength: |
10600nm |
Output Power: |
60W |
Input Power: |
450VA |
Operation Modes: |
Pulsed, Ultra Pulsed, Continuous |
Pulse Width: |
0.02–0.99s |
Pulse Duration: |
1–100μs |
Scan Patterns: |
Triangle, Square, Rectangle, Diamond, Line, Round |
Beam Divergence: |
4mrad |
Focused Spot Diameter: |
120–240μm |
Aiming Beam: |
Infrared Ray (630–650nm, <5mW) |
Beam Delivery: |
7-joint Articulated Arm, 360° Rotation |
Cooling System: |
Internal Circulation Cooling |
Display Screen: |
True Color LCD Touch Screen |
Operation System: |
Microcomputer Control |
Input Voltage: |
AC220V ±10%, 50Hz |
Probes: |
Scanner Probe, Vaginal Probe, Surgical Probe |
Product Name: |
Fractional CO2 Laser |
Technology: |
Medical CO2 Laser Machine |
Function: |
Dermatology CO2 Laser |
Working Mode: |
Single Pulse, Continuous Pulse, Repeated Pulse |
Laser Type: |
Metal Tube |
Laser Wavelength: |
10600nm |
Output Power: |
60W |
Input Power: |
450VA |
Operation Modes: |
Pulsed, Ultra Pulsed, Continuous |
Pulse Width: |
0.02–0.99s |
Pulse Duration: |
1–100μs |
Scan Patterns: |
Triangle, Square, Rectangle, Diamond, Line, Round |
Beam Divergence: |
4mrad |
Focused Spot Diameter: |
120–240μm |
Aiming Beam: |
Infrared Ray (630–650nm, <5mW) |
Beam Delivery: |
7-joint Articulated Arm, 360° Rotation |
Cooling System: |
Internal Circulation Cooling |
Display Screen: |
True Color LCD Touch Screen |
Operation System: |
Microcomputer Control |
Input Voltage: |
AC220V ±10%, 50Hz |
Probes: |
Scanner Probe, Vaginal Probe, Surgical Probe |
The GMS-C6 Fractional CO2 Laser System is a multi-mode professional platform combining fractional scanning and precision laser operation in one system. It integrates a 10600nm CO2 laser source, high-speed scanner, articulated optical arm, touch control system and interchangeable treatment heads.
Operators can adjust laser power, scanning dimensions, point spacing, point duration and scanning mode according to different professional operating requirements. The system provides Fractional, Gynae, Pulsed/Cutting, Vulva and Cosmetology modes, allowing one platform to support a variety of professional aesthetic applications.
![]()
Designed for trained professional operators in aesthetic and beauty-care settings. Typical professional applications include:
The system uses a 10600nm CO2 laser combined with fractional scanning technology. In Fractional Mode, the scanner distributes laser energy into an arranged pattern of individual points across the selected scanning area, with controlled spacing between adjacent points.
The operator can adjust power, point duration, point spacing, scanning dimensions and scanning method through the control interface. Point energy is related to laser power and point duration; increasing point duration increases the energy delivered at each point under the same power setting.
For cutting applications, the system provides dedicated pulsed operating options with adjustable power and pulse width.
Actual application and operating requirements should follow applicable local regulations, product labeling and professional operating guidelines.
| Parameter | Specification |
| Product Model | GMS-C6 |
| Laser Type | CO2 Laser |
| Wavelength | 10600nm |
| Maximum Power | 60W |
| Adjustable Power | 1-60W, 1W step |
| Indication Beam | Diode Laser, 532nm, 5mW |
| Transmission System | 7-Joint Articulated Arm |
| Scan Area | 1×1mm - 20×20mm |
| Scan Patterns | Square, Diamond, Circle, Linear, Hexagon, Triangle |
| Scan Modes | Sequence, Half, Random |
| Point Spacing / Density | 0.1-2.0mm |
| Fractional Point Duration | 0-10ms |
| Cutting Pulse Width | 0.1-100ms |
| Scan Depth | 2mm |
| Working Modes | Fractional / Gynae / Pulsed-Cutting / Vulva / Cosmetology |
| Fractional Head | 1 pc |
| Cutting Head | 1 pc |
| Vaginal Heads | 3 pcs |
| Foot Switch | 1 pc |
![]()
GMS-C6 focuses on parameter flexibility and multi-function integration. Instead of relying on fixed fractional settings, operators can independently control key parameters such as power, scan area, point spacing, point duration, scan pattern and scan mode. This provides greater flexibility for different professional operating preferences and application requirements.
The equipment should be operated by trained professionals who understand the operating procedures, parameter settings and relevant precautions. Appropriate laser protective eyewear should be used during operation, and the user manual should be read carefully before operating the equipment.
Fractional CO2 Laser, CO2 Laser Machine, 10600nm CO2 Laser, Fractional Laser System, CO2 Fractional Machine, Fractional Scanner, CO2 Laser Equipment, Beauty Equipment, Aesthetic Equipment, Professional Beauty Machine, Skin Care Equipment, Fractional Laser Machine, 60W CO2 Laser, Laser Beauty Equipment, Cutting Laser Machine, Fractional Beauty Equipment, Professional Aesthetic Equipment, Beauty Salon Equipment, GMS-C6