Product Details
Place of Origin: Beijing
Brand Name: GOMECY
Certification: CE
Model Number: GMS-980+1470nm Diode laser 6+1 Panacea
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: USD 2580~3180
Packaging Details: Aluminum box
Delivery Time: 5-7 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 500 pcs per month
Product Name: |
Endovenous Laser System |
Technology: |
Dual Wavelength EVLT |
Function 1: |
Varicose Vein Laser |
Function 2: |
Vein Closure Treatment |
Function 3: |
Fiber Optic EVLT |
Transmission: |
Biquartz Optical Fiber |
Aiming Beam: |
650nm Red Diode, <5mW |
Laser Type: |
Pulse, CW, Single |
Wavelengths: |
980nm + 1470nm |
Standard Power: |
20W (980nm), 3W (1470nm) |
Optional Power: |
30W (980nm), 9W (1470nm) |
Pulse Width: |
15–100ms |
Frequency: |
1–20Hz |
Display: |
10.4-inch Color Touchscreen |
Input Power: |
AC 100–240V, 50/60Hz |
Machine Size: |
36 × 37 × 24cm |
Delivery Fiber: |
Bare-tip Or Radial Fiber (200–600μm) |
Product Name: |
Endovenous Laser System |
Technology: |
Dual Wavelength EVLT |
Function 1: |
Varicose Vein Laser |
Function 2: |
Vein Closure Treatment |
Function 3: |
Fiber Optic EVLT |
Transmission: |
Biquartz Optical Fiber |
Aiming Beam: |
650nm Red Diode, <5mW |
Laser Type: |
Pulse, CW, Single |
Wavelengths: |
980nm + 1470nm |
Standard Power: |
20W (980nm), 3W (1470nm) |
Optional Power: |
30W (980nm), 9W (1470nm) |
Pulse Width: |
15–100ms |
Frequency: |
1–20Hz |
Display: |
10.4-inch Color Touchscreen |
Input Power: |
AC 100–240V, 50/60Hz |
Machine Size: |
36 × 37 × 24cm |
Delivery Fiber: |
Bare-tip Or Radial Fiber (200–600μm) |
Endovenous Vein Laser Therapy (EVLT) is a modern alternative to open surgery for varicose veins. It works by delivering controlled laser energy inside the vein through a fine optical fiber:
1470nm wavelength (water absorption): Strongly absorbed by water in the venous wall, producing uniform thermal injury to endothelium and collagen structures, leading to contraction and vein occlusion.
980nm wavelength (hemoglobin absorption): Targets intraluminal blood, supports coagulation and hemostasis during the procedure, improving precision and reducing bleeding.
Combined effect: The synergy of both wavelengths ensures efficient closure with minimal side effects, faster recovery, and better cosmetic outcomes compared to traditional vein stripping.
The treatment relies on fiber pullback under ultrasound guidance, ensuring every centimeter of the incompetent vein is treated without damaging adjacent tissues.
Treatment of great saphenous vein (GSV) insufficiency
Closure of small saphenous vein (SSV)
Recurrent varicosities after conventional surgery or foam therapy
Symptomatic venous reflux causing swelling, leg heaviness, pain, or skin changes
Performed under local anesthesia with minimal discomfort
No surgical incisions, only micro-puncture access
Outpatient procedure with short downtime
High success rate with long-term durability
Aesthetic advantages: no large scars, minimal bruising, natural leg contour
Feature | Specification |
---|---|
Laser Transmission | Biquartz optical fiber |
Aiming Beam | 650nm diode light, <5mW |
Wavelengths | 980nm + 1470nm |
Power Output | Standard: 20W (980nm), 3W (1470nm) |
Optional Power | 30W (980nm), 9W (1470nm) |
Modes | Continuous, Pulsed, Single pulse |
Pulse Duration | 15–100ms adjustable |
Frequency | 1–20Hz |
User Interface | 10.4-inch color touchscreen |
Input Voltage | AC 100–240V, 50/60Hz |
Dimensions | 36 × 37 × 24 cm |
Fiber Options | Bare fiber or radial fiber (200–600µm) |
Radial fiber: Emits circumferential laser light (360°), ensuring complete wall contact and safer heating.
Bare fiber: Forward emission, effective for smaller vessels but requires greater operator precision.
Mapping: Duplex ultrasound to identify vein diameter and reflux source.
Access: Puncture and sheath insertion under ultrasound control.
Fiber Placement: Position fiber tip close to the junction, ensuring accuracy.
Tumescent Anesthesia: Infiltrate around vein for anesthesia, compression, and heat protection.
Energy Delivery: Activate laser while slowly pulling back the fiber for controlled vein closure.
Verification: Confirm occlusion by ultrasound.
Post-care: Apply compression and encourage walking.
User-friendly touchscreen interface with quick settings adjustment
Real-time pilot beam for precise fiber localization
Stable power delivery across both wavelengths
Compact design suitable for outpatient centers
Complete clinical and duplex ultrasound assessment.
Patient should avoid anticoagulants if possible (per physician approval).
Exclude patients with deep venous thrombosis or severe arterial disease.
Apply compression stockings for 7–14 days depending on case severity.
Patient encouraged to walk immediately and maintain normal activity.
Avoid hot baths, heavy exercise, or long immobility for at least 48 hours.
Follow-up duplex ultrasound to confirm vein closure and rule out complications.
Current pregnancy or breastfeeding
Acute deep vein thrombosis or pulmonary embolism history
Severe peripheral arterial disease
Active local infection or skin ulcer at puncture site
Known photosensitivity disorders
Patients unable to walk post-procedure
Better energy absorption balance: Water + hemoglobin targeting for safer closure
Less thermal spread: 1470nm reduces postoperative pain and bruising
Customizable: Pulsed settings minimize carbonization risk
High closure rates: Comparable or superior to single wavelength systems
Flexible fiber compatibility: Adaptable to different vein diameters and techniques