Product Name: |
Reliable PEMF Therapy Machine |
Technology: |
Clinical Body Recovery Device |
Function 1: |
6 Tesla Professional PEMF |
Function 2: |
Performance Magnetic Therapy Equipment |
Function 3: |
Professional PEMF Recovery System |
Power: |
1000W |
Magnetic Flux Density: |
6T |
Output Pulse Frequency: |
1Hz - 100Hz |
Display: |
10.4-inch Capacitive Screen |
Fuse Rating: |
10A |
Gross Weight: |
55kg |
Package Dimensions: |
113cm*57cm*49cm |
Power Supply: |
AC110V-220V |
Feature 1: |
Clinical Grade PEMF Device |
Feature 2: |
Reliable Magnetic Stimulation Therapy |
Product Name: |
Reliable PEMF Therapy Machine |
Technology: |
Clinical Body Recovery Device |
Function 1: |
6 Tesla Professional PEMF |
Function 2: |
Performance Magnetic Therapy Equipment |
Function 3: |
Professional PEMF Recovery System |
Power: |
1000W |
Magnetic Flux Density: |
6T |
Output Pulse Frequency: |
1Hz - 100Hz |
Display: |
10.4-inch Capacitive Screen |
Fuse Rating: |
10A |
Gross Weight: |
55kg |
Package Dimensions: |
113cm*57cm*49cm |
Power Supply: |
AC110V-220V |
Feature 1: |
Clinical Grade PEMF Device |
Feature 2: |
Reliable Magnetic Stimulation Therapy |
GOMECY PMCT PEMF 687 Double Magneto Therapy Machine with Two Applicators and Air Cooling
Product Description
The GMS PMCT 687 is a floor standing double magneto therapy system designed for professional physiotherapy and rehabilitation settings. Its two magnetic applicators and positioning arms help operators arrange localized sessions while keeping the applicators supported. The wheeled base and front handrail assist movement within a treatment room.
The system generates pulsed magnetic fields for peripheral muscle and nerve stimulation. Direct skin contact is not required, and applicators can be positioned near the selected area over suitable clothing. Touchscreen controls provide access to session settings, including applicator intensity and time. Settings and positioning should be selected by trained personnel after suitability screening.
![]()
· Two magnetic applicators with supported positioning.
· 6 T magnetic induction intensity specified as the total across two channels.
· Frequency range of 0.01–100 Hz according to the current product specification.
· Pulse duration ≥340 μs with a stated tolerance of ±20 μs.
· Air cooling without a liquid coolant circuit.
· Touchscreen interface and movable wheeled cabinet.
Intended for professionally supervised musculoskeletal care, muscle relaxation and rehabilitation support. Potential session objectives include managing muscle discomfort, supporting local circulation and helping address muscle tension.
![]()
The system operates on electromagnetic induction. A changing current in the applicator coil produces a time varying magnetic field. This field can induce an electric field in nearby tissue. When the induced stimulation is sufficient, it can activate peripheral nerves and muscles. The response depends on settings, coil position, distance and individual tissue characteristics.
Magnetic stimulation does not require skin electrodes to conduct current into the target area. The applicator is placed near the selected region and held by its positioning arm.
![]()
Localized muscle care and supervised musculoskeletal rehabilitation sessions.
Integration into an individualized program alongside other suitable rehabilitation activities.
Professionally assessed muscle relaxation and recovery support after activity.
Supported applicator placement and touchscreen setup for structured sessions.
Shoulder, elbow, wrist, hip, thigh, knee, ankle and foot regions may be considered where allowed by the instructions and individual screening. Selection of an area does not establish suitability for every user. Do not infer permission to stimulate restricted organs or regions from a general body area label.
![]()
Check the ordered voltage version, applicator connections and support arm stability before use. Review contraindications, position the applicator, select appropriate settings and monitor the session.
| Parameter | Specification |
| Brand | GOMECY |
| Model | GMS PMCT 687 |
| Product type | Double magneto therapy system |
| Channels and applicators | 2 channels with 2 magnetic applicators |
| Magnetic induction intensity | 6 T total across 2 channels |
| Frequency | 0.01–100 Hz |
| Pulse duration | ≥340 μs (±20 μs) |
| Maximum magnetic induction change rate | ≥40 kT/s–80 kT/s as supplied |
| Cooling system | Air cooling |
| Voltage and mains frequency | AC 110 V or AC 220 V; 50–60 Hz |
| Rated power | 1000 W |
| Fuse rating | 15 A |
| Control interface | Touchscreen |
| Applicator positioning | Adjustable support arms |
| Package dimensions | 113 × 57 × 49 cm |
![]()
FAQ
1. What is the frequency range?
The current supplied range is 0.01-100 Hz.
Direct skin contact is not required. Positioning over suitable clothing may be possible when consistent with the operating instructions.
Yes, Handle A and Handle B intensity and time controls.
Choose the AC 110 V or AC 220 V version appropriate for the destination. Confirm voltage and frequency on the equipment label before connection.
This listing covers double magneto therapy only.
No. Settings and session duration require individual assessment by trained personnel.
Trained personnel in a professional setting should operate it after reviewing the full instructions and contraindications.
Keep the unit clean and dry, inspect connections, and leave ventilation clear.
One year for the main unit and six months for the handles.
![]()
Double Magneto Therapy Machine Magnetic Stimulation System Dual Channel Magnetic System Two Applicator Magneto System Air Cooled Magnetic System Magnetic Physiotherapy Equipment Professional Rehabilitation Equipment Adjustable Support Arm Touchscreen Magneto Machine GMS PMCT 687