Product Details
Place of Origin: BEIJING
Brand Name: GOMECY
Certification: CE, ISO13485
Model Number: PMCT 685
Payment & Shipping Terms
Minimum Order Quantity: 1 Unit
Packaging Details: aluminum alloy box
Delivery Time: 7 days
Payment Terms: T/T, , Western Union, online order
Supply Ability: 200 units per month
Product Name: |
Gomecy 2 Handles 6 Tesla Professional PMST Therapy Device For Physiotherapy Clinics |
Function: |
Body Pain Relieve Pemf 8000 Machine Pmst Loop Therapy Home Use Device |
Magnetic Intensity: |
6 Tesla Or 7Tesla Optional |
Technologies: |
Pulse Electromagetic Field |
Feature: |
Body Pain Relief After Sport Recovery |
Power Intensity: |
6 Tesla Or Customize |
Frequency: |
1-100Hz |
Power Supply: |
AC110/60Hz, AC220V/50Hz |
Type: |
Physiotherapy Equipment Home Use Commercial Use |
Screen Size: |
15.6-inch Touch Screen |
Spot Size: |
Approx. 45mmX45mm |
Wavelengths: |
685nm 3pcs; 830nm *9pcs Laser Therapy |
Product Name: |
Gomecy 2 Handles 6 Tesla Professional PMST Therapy Device For Physiotherapy Clinics |
Function: |
Body Pain Relieve Pemf 8000 Machine Pmst Loop Therapy Home Use Device |
Magnetic Intensity: |
6 Tesla Or 7Tesla Optional |
Technologies: |
Pulse Electromagetic Field |
Feature: |
Body Pain Relief After Sport Recovery |
Power Intensity: |
6 Tesla Or Customize |
Frequency: |
1-100Hz |
Power Supply: |
AC110/60Hz, AC220V/50Hz |
Type: |
Physiotherapy Equipment Home Use Commercial Use |
Screen Size: |
15.6-inch Touch Screen |
Spot Size: |
Approx. 45mmX45mm |
Wavelengths: |
685nm 3pcs; 830nm *9pcs Laser Therapy |
| Technology | Gomecy Professional PMST 685 Magnetic Therapy Equipment For Physiotherapy Clinics |
|---|---|
| Product Name | PMCT 685 optional |
| Function |
|
| Applications | Physical therapists, sports medicine, rehabilitation centers, veterinarians, and home use |
| Magnetic intensity | customization |
| Pulse Frequency | 1-100Hz |
| Pulse Continuous Time | ≥340μs (±20μs) |
| IP rating | IP 31 |
| Attached handles | PMST magnetic handles 2 pcs, if need laser therapy handle, please chat with us. |
| Package size | 116cm*56cm*61cm |
| Package Weight | 68 KG |
1. Upgraded laser wavelengths (685nm + 830nm) for deeper photobiomodulation effects
2. Better tissue regeneration support
3. More suitable for:
a.Chronic pain
b.Tendon injuries
c.Nerve recovery
d.Post-surgical rehabilitation
e.Wound healing
4. Higher perceived value for clinics offering premium rehabilitation programs
| Feature | PMCT685 |
| Magnetic Therapy | Yes |
| Handles | 2 PCS |
| Magnetic Intensity | 6 Tesla |
| Treatment Depth | Deep tissue penetration |
| Main Applications | Pain relief, tissue repair, nerve recovery, wound healing, rehabilitation |
| Suitable Users | Professional physiotherapy clinics, sports medicine centers |
| Clinical Advantage | Stronger Pulse Magnetic Therapy Energy output, 2 channels |
| Area | Energy | Frequency | ||
| F1 | F2 | F3 | ||
| Wrist | 30 | 27 | 25 | 7 |
| Elbow | 30 | 27 | 25 | 7 |
| Shoulder | 50 | 31 | 29 | 9 |
| Groin | 45 | 26 | 22 | 6 |
| Hip | 60 | 31 | 29 | 10 |
| Thigh | 50 | 27 | 25 | 7 |
| Lumbar Vertebra | 50 | 31 | 28 | 8 |
| Cervical Vertebra | 50 | 27 | 25 | 7 |
| Knee | 55 | 31 | 29 | 9 |
| Foot/Ankle | 40 | 27 | 25 | 7 |
Treatment Working Theory
(1) TERAPIA Magnetica
According to the principle of Faraday electromagnetic induction, a large amount of energy is quickly discharged from large-capacity storage capacitors to the coil. The coil is stimulated by strong current to produce pulse magnetic field, it can penetrate clothing, bones and other tissues, generate inductive electric fields in stimulating parts, causing excitement/suppression activities of nerve cells, and then generate a series of physiological biochemical reactions.
Magneto Therapy pulses a magnetic field into the body, creating an extraordinary healing effect. The results are less pain, reduction in swelling, and increased range of motion in the affected areas.
It can be divided into low-frequency TMS (≦1Hz) and high-frequency TMS (≧5Hz) according to different frequencies.
Different frequency TMS is different in regulating the sports cortex:
high-frequency TMS: Increase the excitement of the cortex;
low-frequency TMS: decrease the excitement of the cortex.
TMS is divided into sTMS, pTMS, and rTMS according to the stimulus mode.
sTMS: A single-time magnetic field with a non-fixed frequency is used to observe the instantaneous effect, and it is mostly used for conventional electrical physiological examinations.
pTMS: Based on a specific time interval and intensity, 2 stimuli is given to one specific area or two different parts, which are mostly used to study the easilyization and inhibitory effects of the nerves.
rTMS: During a certain area, the magnetic field is changed at a certain frequency. When the stimulus stops, there is still a continuous biological effect. It is a powerful tool for brain function research and clinical treatment.
T Loo Duo PEMF
PMCT 685 Application
(1) TERAPIA Magnetica
It uses a magnetic field to stimulate muscle tissue and nerves through clothes and skin without decaying, so that it generates an inductive current, a non-invasive, painless stimulus to tissue and peripheral nerves, which can accelerate metabolism and blood circulation, enhance the body's immunity, soothe pain, reduce muscle soreness, restore damaged cells to normal health, and regulate and improve physical function.
① Muscle pathology (contracture, muscle tears, bruises, and swelling).
② Bone injuries, osteoarticular distractions, and wear of the joints (shoulder, hips, knees, ankle joints).
③ Pathology of the elbow, wrist, and arms (epicondylitis, tendinitis, carpal tunnel syndrome).
④ Thoracic vertebral pathology.
⑤ Inflammation and damage to the Achilles tendon and ligament.
⑥ Tendonitis in the shoulder joint area and chronic edema.
Machine display
![]()
![]()
PMCT-685 Advantages Machine PM
![]()
![]()
Q & A
(1) Is there any radiation damage from magnetic stimulation?
No. People confuse ionizing radiation with electromagnetic radiation. X-rays, CT, etc. produce ionizing radiation, which can cause harm to living beings; and electromagnetic radiation is everywhere, such as mobile phones, microwave ovens, induction cookers, TVs, microphones, etc. Magnetic stimulation generate electromagnetic radiation just like mobile TVs, so they will not cause radiation damage. Therefore, you can accept the treatment with no worry.
(2) Why is there noise during treatment?
The noise generated during treatment is caused by the expansion and impact of the wires in the coil when the power is turned on, which is unavoidable.
(3) How is the cooling system?
Excellent. After continuous improvement, the magnetic stimulator has been able to work continuously at room temperature of 26°C.
(4) How does magnetic stimulation work?
According to Faraday's theorem of electromagnetic induction, a time-varying magnetic field can induce an electric field. When an excitable tissue is in a time-varying magnetic field, an induced electric field and an induced current are generated in the tissue. When the inductive current exceeds the tissue's excitement threshold, it causes the cell membrane to exfoliate and excite the tissue.
(5) What is the difference between the induced current produced by magnetic stimulation and the current produced by electrical stimulation?
The same point: all excitable tissues such as nerves and muscles are stimulated by electric current.
Differences: Electrical stimulation requires electrodes to be in contact with the skin, mucous membranes, etc., to conduct current to the target tissue; while magnetic stimulation does not require electrodes and does not need to be in contact with the skin or mucous membranes, it is a time-varying magnetic field generated by a stimulation coil that induces an electric current in the body.
IMPORTANT: Before starting the equipment correctly, please follow the installation instructions. Any damages caused by incorrect operations will void the warranty.
Safety Information:
Thank you for choosing our products! This user instruction is specially designed for the safety of you and others. Please read the instructions carefully before installing or using the machine and follow them when using. The company does not take any responsibility for any accidents and problems caused by improper operation or mistakes, excluding quality problems.
Electrical Safety:
Before installing the machine, make sure that your local electric network complies with the voltage and frequency indicated on the tag on the rear panel. Otherwise, the machine may be damaged incase of excessive current or voltage rise.
Never touch the machine with damp or wet hands or feet.
It is dangerous to change or try to modify the function of this machine in anyway.
Do not attempt to operate this unit if the power cord has been frayed or broken.
Do not spill water or other liquids into or onto your unit.
During long periods of non-use, disconnect the unit’s main power.
Safety Rules When Installing
Place the machine on a stable and secure base. It should not be subjected to any jolts or vibrations.
Never expose the unit to too high(>40ºC) nor too low temperature(<5ºC).
NEVER EXPOSE THE UNIT TO RAIN OR ANY OTHER HUMIDITY..
Do not expose the unit to direct sunshine or install the unit close to a source of heat(central heating, radiator…); otherwise the screen may be damaged.
Do not cover or block the ventil at or behind the unit.
Safety Rules When in Use
Well clean areas to treat before treatment.
Never touch the machine with damp or wet hands or feet.
Operate Interface Instruction
Treatment screen interface.
Make sure the power line has been installed correctly; make sure the hand pieces are well connected with the equipment; ensure the circuit breaker (if any) at the back of the machine is pressed to “on”. The working menu will appear automatically. Choose the Language. Choose the right parameter to do the treatment according to the needs of the customer.
Turn on the machine and you can see the welcome screen and main selection interface.
o